Schneider Electric 3 PH SSR 530VAC 25A 230
Product details
Load current minimum: 0.1 A
Load current maximum: 25 A
Mounting type: Front panel mounting
Load voltage minimum: 48 V AC
Load voltage maximum: 530 V AC
Control voltage minimum: 180 V AC
Control voltage maximum: 280 V AC
Switching type: AC circuit
Contact arrangement: 3 pole normally open contact
Connection type: Screw
Output circuit: SCR
Turn on time maximum: 20 ms
Dimensions: 101.3 x 97.8 x 35.5 mm
Standards met: CE, CSA, UL
Zelio SSP3 semiconductor relays from Schneider Electric provide a compact and innovative solution for a variety of interface control and load switching applications. The SSP series of front panel mount relays offer complete semiconductor control and switching solutions. SSP relays enable switching at voltage zero crossing for resistive loads and random switching for inductive loads. With options for 1-phase and 3-phase configurations and current ratings from 6 A to 55 A, they ensure easy maintenance, high switching frequency, resistance to shock, vibration, and pollution, and a long life.
input voltage | 48 V |
Output voltage | 530 V |
Electric current output | 0.10 A |
Output current type | AC |
Number of poles | 3x |
Item number | 9872441 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer No. | SSP3A225P7T |
Release date | 8.10.2018 |
input voltage | 48 V |
Output voltage | 530 V |
Electric current output | 0.10 A |
Output current type | AC |
Number of poles | 3x |
Smart home | Not compatible |
Country of origin | Mexico |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Length | 41 mm |
Width | 104 mm |
Height | 74.60 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
- 5.Finder0,1 %
- 6.Eaton0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly1 day
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 7.Finder2,6 %
- 8.Aqara3 %
- 9.Schneider Electric3,1 %
- 10.Eltako3,6 %
- 11.Eaton3,7 %