TE Sensors Rope Pull Switch, LH, B/Reset, w/o Light
Product details
Area: Pre-Sales
Series: XY2-CE
Reset Button: Yes
Contact Configuration: Normally Closed/Normally Open
Mounting Position: Left
Maximum Cable Span: 50 m
Maximum Current: 10 A
Maximum Voltage: 300 V
Number of Cable Entries: 3
Cable Entry Size: 0.5 inch NPT
Width: 7.8 inches
EN/ISO 13850:2006. The XY2 CB switch must not be used if the system requires an angled installation of the release wire; this is possible with the XY2 CE. In this case, the sum of the angles through which the release wire is bent must not exceed 180°. Emergency stop pull cord switches XY2CE & XY2CB, Telemecanique. These emergency stop pull cord switches are designed to reduce the risk of injury to individuals and damage to machines or production products. They can be activated by a person with a single movement when a normal emergency stop function is not available, and they will also activate if the release wire breaks. The switches feature forced opening contacts, with the activation of the switch occurring through forced operation. The switch locks in the activated position (normally open safety contacts). The normally closed contact is solely for signaling. Includes a reset button, which allows the safety contacts to be closed again. Restarting the machine must only be done by manually operating a control device within the machine's start circuit, which is located some distance from the release wire switch. The recommended distance between cable holders is 15 m. (For XY2-CB30, a distance of 20 m is recommended.) The XY2 CE1A296 comes with an indicator light (direct supply).