ABB Automatic circuit breaker
Product details
The S200MT series circuit breakers are specifically designed for the rail sector and protect cables and lines against overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, DIN VDE 0660-101 or IEC/EN 60947-2, hazard level R26/HL3 according to DIN EN 45545, and requirement class 3 according to NF F 16-101/102 (I2-F3), as well as category 1 - class A/B (mounted) according to IEC 61373. Their patented terminal block ensures easy and secure connection and handling through a pressure plate. For better visibility during wiring, the connection opening for cables is positioned above the connection opening for the phase rail. The actual switching position is displayed through a viewing window, even when the switch lever is blocked. Conductor cross-sections of up to 25 mm² can be directly connected to the device via the terminal block with insulation in protection class IP20. The extensive range of accessories provides everything you need for your installation tasks. Each device undergoes three rigorous tests for quality and performance before delivery.
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
number of poles | 1 |
Item number | 36937583 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 2CDS271445R0158 |
Release date | 5.7.2023 |
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
number of poles | 1 |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 440 V |
Residual current (rated differential current) | 15000 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
- 5.Hager0,2 %
- 7.Steffen0,7 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Brennenstuhl1,1 %
- 3.Schneider Electric1,3 %
- 4.ABB1,9 %
- 5.Eaton3,3 %
- 6.Siemens3,6 %