Product details
The S 200 M UC series circuit breakers protect cables and wires from overload and short circuits in accordance with DIN VDE 0100-430 and DIN VDE 0100-530. They comply with the construction regulations DIN VDE 0641-11 or IEC/EN 60898-1, and DIN VDE 0660-101 or IEC/EN 60947-2. Their patented terminal block ensures easy and secure connection and handling through a pressure plate. For better visibility during wiring, the connection opening for wires is located above the connection opening for the phase rail. Conductor cross-sections of up to 35 mm² can be directly connected to the device via the terminal block with insulation in protection class IP20. The extensive range of accessories provides everything you need for your installation tasks. The S200 M UC impresses with its high short-circuit breaking capacity and flexible use for AC and DC applications. Each device undergoes three intensive tests for quality and performance before delivery.
Circuit breaker type | Miniature circuit breaker |
Length | 69 mm |
Width | 70 mm |
number of poles | 4 |
Item number | 33787901 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 2CDS274061R0204 |
Release date | 17.5.2023 |
Colour | White |
Exact colour description | White |
Circuit breaker type | Miniature circuit breaker |
number of poles | 4 |
Tripping characteristic | C/10 ka |
Rated current | 20 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 400 V |
Residual current (rated differential current) | 10 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 69 mm |
Width | 70 mm |
Height | 88 mm |
Weight | 500 g |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 4.Eaton0,2 %
- 5.ABB0,3 %
- 5.Hager0,3 %
- 7.Steffen0,6 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- LegrandNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 4.Legrand2 %
- 4.Siemens2 %
- 6.ABB2,2 %
- 7.Eaton4,1 %
- 8.Hager4,9 %