Eaton RCD/LS combination PXK-C40/1N/003-F
Manufacturer: Eaton
Designation: RCD/LS combination 40 A, 30 mA, C
Type: PXK-C40/1N/003-F
Number of poles (total): 2
Number of fused poles: 1
Rated voltage: 240 V
Rated insulation voltage Ui: 440 V
Rated impulse withstand voltage Uimp: 4 kV
Rated current: 40 A
Rated residual current: 0.03 A
Residual current type: A
Energy limitation class: 3
Rated breaking capacity according to EN 61009: 10 kA
Rated breaking capacity according to IEC 60947-2: 0 kA
Rated breaking capacity Icn according to EN 61009-1: 10 kA
Tripping characteristic: instantaneous
Surge current withstand: 3 kA
Voltage type: AC
Frequency: 50 Hz
Tripping characteristic: C
Switching neutral: yes
With interlocking device: no
Overvoltage category: 3
Pollution degree: 2
Ambient temperature during operation: -25 to 40 °C
Width in pitch units: 2
Installation depth: 75.5 mm
Flush mounting: no
False tripping protection: yes
Protection class (IP): IP20
Connectable conductor cross-section solid: 1 to 25 mm²
Connectable conductor cross-section stranded: 1 to 25 mm²
Eaton FI/LS combination PXK-C40/1N/003-F: further details
High-quality residual current circuit-breaker/line circuit-breaker combination, mains-voltage-independent, contact position indicator red-green, terminal backsplash protection, tristable latching slide - enables removal from an existing busbar system, extensive range of accessories for retrofitting, large selection of rated residual currents, rated currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (site and outdoor distribution boards) down to -25 °C.
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Width | 2 mm |
number of poles | 2 |
Mounting type | Top-hat rail |
Item number | 31984002 |
Manufacturer | Eaton |
Category | Residual-current device |
Manufacturer no. | 193541 |
Release date | 24.10.2022 |
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Top-hat rail |
number of poles | 2 |
Tripping characteristic | C |
Rated current | 40 A |
Rated current | 0.03 A |
Rated voltage | 230 V |
voltage type | AC |
Rated insulation voltage Ui | 440 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Romania |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Width | 2 mm |
Product Safety |
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: GalaxusHow many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: GalaxusUnfortunately, we don't have enough data for this category yet.
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus