Schneider Electric A9N85 FiBlock Vigi C20 3p
Product details
FI-Block Acti 9 Vigi C120. 3-pole, rated residual current 300 mA, Type A, SI, operating voltage (Ue) 230-415 V AC, insulation voltage (Ui) 500 V AC. Can be mounted on the right side of circuit breakers from the C120 series. The tripping due to residual current is indicated by a red mechanical display on the knob. Terminals IP 20. Test button for regular function testing. Technology of the tripping unit: thermomagnetic. Additional plug-in auxiliary modules (optional): fault indication switch, auxiliary switch, undervoltage release, surge protection release, working current release. The Vigi C120 FI-Block complies with the following standards: IEC/EN 61009-1.
Circuit breaker type | Miniature circuit breaker |
Length | 73 mm |
Width | 171 mm |
number of poles | 3 |
Mounting type | Top-hat rail |
Item number | 12900477 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | A9N18595 |
Release date | 12.3.2020 |
External links |
Colour | White |
Exact colour description | White |
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 3 |
Tripping characteristic | A |
Rated current | 125 A |
Rated current | 0.3 A |
Rated voltage | 230 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.30 A |
Protection type (IP code) | IP20 |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 73 mm |
Width | 171 mm |
Height | 95 mm |
Weight | 500 g |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 1.Brennenstuhl0 %
- 2.Steffen0,3 %
- 3.Schneider Electric1,2 %
- 4.ABB1,6 %
- 5.Siemens3 %