Schneider Electric Main emergency stop switch VCD01
Only 3 pieces in stock at supplier
Product details
Number of poles: 3
Range: TeSys
Series: VARIO
Power: 11 W
Protection class: IP20, IP65
Padlock option: Yes
Operating voltage: 690 Vac
Electrical phases: 3
Switching capacity: 8 kV
Length: 60 mm
Minimum operating temperature: -20 °C
The values in the price table for the rated operating voltage refer to a voltage of 230/240 V, and the numbers in parentheses refer to a voltage of 690 V. The higher rated current applies to open-air use, while the lower rated current applies to use in an enclosure. Disconnect switch, front mounting/door fastening. Customizable by simply adding an auxiliary contact, neutral contact, or up to 3 main contacts to the 3-pole base switch. Suitable for switching main power/emergency stop at 690 V rated voltage. Protection against ingress of liquids according to IP55. Fully compliant with BS/EN 60947-3. Delivered as a complete kit in one package.
Nominal current | 20 A |
Nominal voltage | 690 V |
Protection type (IP code) | IP65 |
Item number | 9731105 |
Manufacturer | Schneider Electric |
Category | Mobile power distributors |
Manufacturer no. | VCD01 |
Release date | 24.9.2018 |
Colour | Red |
Exact colour description | Red |
Nominal current | 20 A |
Nominal voltage | 690 V |
mounting type | Front panel mounting |
Number of poles | 3x |
Contact Configuration | 3 normally open contacts |
Actuator Type | Short twist grip |
Protection type (IP code) | IP65 |
Country of origin | Czech Republic, France |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 15,72 kg |
Climate contribution | EUR 0,40 |
Items per sales unit | 1 pcs. |
Width | 86 mm |
Length | 123 mm |
Height | 74 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Mobile power distributors» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Eaton0 %
- 2.MeanWell0,1 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- EatonNot enough data
- MeanWellNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Mobile power distributors» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.MeanWell2,8 %
- 2.Eaton5,2 %