Schneider Electric Motor protection switch GV2LE03
Product details
Schneider Electric motor-protective circuit-breaker GV2LE03
Manufacturer: Schneider Electric
Designation: Motor-protective circuit-breaker
Type: GV2LE03
Setting range of instantaneous short-circuit release: 5 A
With thermal protection: No
Phase loss sensitive: Yes
Tripping technology: Rated operational voltage: 690 V
Rated continuous current Iu: 0.4 A
Rated operational power at AC-3, 230 V: 0.06 kW
Rated operational power at AC-3, 400 V: 0.09 kW
Type of connection main circuit: Screw connection
Design of the actuating element: Toggle lever
Unit design: Complete unit in enclosure
With integrated auxiliary switch: No
With integrated undervoltage release: No
Number of poles: 3
Rated short-circuit breaking current Icu at 400 V, AC: 100 kA
Protection class (IP): IP20
Height: 89 mm
Width: 45 mm
Depth: 78.5 mm
Schneider Electric GV2LE03 motor-protective circuit-breaker: more details
Motor-protective circuit-breaker with thermal and magnetic tripping. These devices are easy to use and set up, with compact and ergonomic products for starter motor and stop motor requirements.
Circuit breaker type | Motor protection switch |
Length | 78.50 mm |
Width | 45 mm |
number of poles | 3 |
Item number | 33587055 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | GV2LE03 |
Release date | 17.5.2023 |
Circuit breaker type | Motor protection switch |
Mounting type | Screw fastening |
number of poles | 3 |
Tripping characteristic | Sluggish --- |
Rated voltage | 690 V |
voltage type | AC |
Protection type (IP code) | IP20 |
Country of origin | France |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 78.50 mm |
Width | 45 mm |
Height | 89 mm |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 1.Brennenstuhl0 %
- 2.Steffen0,3 %
- 3.Schneider Electric1,2 %
- 4.ABB1,9 %
- 5.Siemens3,1 %