Schneider Electric Pressure switch XMLB020A2S12EX
Product details
TE Sensors pressure switch XMLB020A2S12EX
Manufacturer: TE Sensors
Designation: Pressure switch 20 bar
Type: XMLB020A2S12EX
Suitable as a monitor: Yes
Suitable as a 2-point controller: Yes
Suitable as a limiter: Yes
Max. working pressure: 20000 hPa
Switch-on pressure: 1.3 to 20 bar
Initial setting: 1300 to 20000 hPa
Switch-off pressure: 0.3 to 18.4 bar
Final setting: 300 to 18400 hPa
Pressure switching differential: 11 bar
Max. test pressure: 45 bar
Burst pressure: 90 bar
Medium temperature: -20 to 60 °C
Thread size: Other
Rated operating voltage Ue at AC 50 Hz: 120 to 240 V
Rated operating voltage Ue at AC 60 Hz: 120 to 240 V
Rated operating voltage Ue at DC: 0 V
Initial value pressure measuring range: 0 Pa
Final value pressure measuring range: 0 Pa
Rated operating power at AC-3, 400 V: 0 kW
Switching capacity at AC-3, 240 V: 0 kA
Rated operating current Ie at AC-1, 400 V: 0 A
Rated operating current Ie at AC-3, 400 V: 0 A
Number of auxiliary contacts as changeover contacts: 1
Type of electrical connection: Screw connection
Adjustable current range: 0 A
With manual override: No
With manual on/off switch: No
Electronic version: No
With display: No
Explosion-proof: Yes
Protection class (IP): IP66
Protection class (NEMA): Other
Height: 113 mm
Width: 35 mm
Depth: 75 mm
TE Sensors pressure switch XMLB020A2S12EX: Further details XMLB pressure switch 20 bar, adjustable hysteresis, 2 switching points, 1 NC or 1 NO contact, connection terminals.
Protection type (IP code) | IP66 |
Item number | 33590809 |
Manufacturer | Schneider Electric |
Category | Mobile power distributors |
Manufacturer no. | XMLB020A2S12EX |
Release date | 17.5.2023 |
input voltage | 120 - 240 V |
Protection type (IP code) | IP66 |
Country of origin | France |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 pcs. |
Width | 35 mm |
Length | 75 mm |
Height | 113 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Mobile power distributors» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Eaton0 %
- 1.MeanWell0 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- EatonNot enough data
- MeanWellNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Mobile power distributors» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.MeanWell4,6 %
- 2.Eaton10,7 %