Schneider Electric Circuit Breaker GV2RT07
Manufacturer: Schneider Electric
Designation: Circuit Breaker 2.50 A
Type: GV2RT07
Overload Release Current Setting: 1.6..2.5 A
Setting Range of Instantaneous Short-Circuit Release: 51 A
With Thermal Protection: Yes
Phase Failure Sensitive: Yes
Release Technology: Thermomagnetic
Rated Operating Voltage: 690 V
Rated Continuous Current Iu: 2.5 A
Rated Operational Power at AC-3, 230 V: 0.37 kW
Rated Operational Power at AC-3, 400 V: 0.75 kW
Power Loss: 2.5 W
Connection Type for Main Circuit: Screw Connection
Actuating Element Design: Toggle Lever
Device Design: Complete Device in Housing
With Integrated Auxiliary Switch: No
With Integrated Undervoltage Release: No
Number of Poles: 3
Rated Short-Circuit Breaking Capacity Icu at 400 V, AC: 100 kA
Protection Class (IP): IP20
Height: 89 mm
Width: 45 mm
Depth: 78.5 mm
Schneider Electric Circuit Breaker GV2RT07: Additional Details
Motor protection circuit breaker with thermal and magnetic release. These devices are easy to use and set up, featuring compact and ergonomic products for starter and stop motor applications.
EAN: 3389110520637.
Circuit breaker type | Circuit breaker, Motor protection switch |
number of poles | 3 |
Width | 45 mm |
Item number | 9718165 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer No. | GV2RT07 |
Release date | 24.9.2018 |
Colour | White |
Exact colour description | White |
Circuit breaker type | Circuit breaker, Motor protection switch |
number of poles | 3 |
Rated voltage | 690 V |
voltage type | AC |
Protection type (IP code) | IP20 |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Items per sales unit | 1 pcs. |
Width | 45 mm |
Height | 89 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
- 8.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Eaton0,7 %
- 2.Max Hauri0,7 %
- 4.Schneider Electric1,3 %
- 5.ABB1,8 %
- 6.Siemens2,6 %