Siemens RCBO 4 Pole Type B 30mA 10kA C 100A
Product details
Area: Sentron
Series: 5SU1
Rated Current: 100 A
Tripping Sensitivity: 30 mA
Number of Poles: 4P
Mounting Type: DIN Rail Mounting
RCCB with circuit breaker from the 5SU1 series. A series of RCCBs with circuit breakers in a compact design for a differential current of up to 30 mA, used for the protection of personnel and materials, as well as for fire protection and protection against direct contact. RCCBs with circuit breakers consist of a part for fault current detection and a part for overload detection. They are equipped with a delayed, overload/time-dependent thermal tripping (bimetal) for low overloads and an instantaneous electromagnetic tripping for higher overloads and short-circuit currents. The conductor connection can be easily checked before the busbar. A large accessible wiring area allows for easy insertion of conductors into the terminals. The short-circuit withstand strength of over 1 kA ensures safe and reliable operation. All additional components for miniature circuit breakers can be retrofitted on the right side.
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Flush-mounted |
number of poles | 4 |
Length | 70 mm |
Item number | 9733556 |
Manufacturer | Siemens |
Category | Residual-current device |
Manufacturer No. | 5SU1374-7AK81 |
Release date | 24.9.2018 |
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Flush-mounted |
number of poles | 4 |
Tripping characteristic | C |
Rated current | 100 A |
Rated voltage | 400 V |
voltage type | AC |
Insulation voltage (Ui) | 440 V |
Residual current | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 18,08 kg |
Climate contribution | EUR 0,44 |
Items per sales unit | 1 pcs. |
Length | 70 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Eaton0 %
- 1.Max Hauri0 %
- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SiemensNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Max Hauri0,7 %
- 4.Schneider Electric1,3 %
- 5.ABB1,8 %
- 6.Siemens2,6 %
- 7.Hager4,5 %