Best selling Energy monitors from Eltako

On this page you’ll find a ranking of the best Energy monitors from Eltako. To give you a quick overview, we’ve added the most important product details. This page always stays fresh and updates automatically.

1. Eltako Three-phase meter MID calibrated

Only calibrated meters are approved for electricity billing according to § 25 of the German Calibration Act. Non-compliance is an administrative offense under § 19. Maximum current is 3 x 80 A, with a standby loss of only 0.5 watts per path. This is a modular device for mounting on DIN rail EN 60715 TH35. It occupies 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). Equipped with S0 interface. The directly measuring three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured or displayed. It can connect 1, 2, or 3 external conductors with currents up to 80 A. The starting current is 40 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a bar that blinks 100 times per kWh on the display. 

2. Eltako DSZ15EN

Maximum current 3x80A, standby loss only 0.5 watts per path. Modular device for mounting on DIN rail EN 60715 TH35. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With S0 interface. The directly measuring three-phase energy meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 external conductors with currents up to 80A can be connected. The starting current is 40 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a bar that blinks 100 times per kWh on the display. It can also be used as a 2-tariff meter as standard: applying 230V to terminals E1/E2 switches to a second tariff. To the right of the display are the MODE and SELECT buttons. 

3. Eltako DSZ15WD-3X5A MID

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is considered an administrative offense under §19. This is a transformer three-phase meter with adjustable transformer ratio and MID. Maximum current is 3x5A, with a standby loss of only 0.5 watts per path. It is a modular device for mounting on a DIN-EN 60715 TH35 rail. It occupies 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). Equipped with an S0 interface. This three-phase meter measures active energy based on the currents flowing through the transformers. The self-consumption of only a maximum of 0.5 watts active power per path is not measured or displayed. It can connect 1, 2, or 3 transformers with secondary currents up to 5A. The starting current is 10mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a bar that blinks 10 times per kWh on the display. 

4. Eltako MBus three-phase meter MID calibrated

Only calibrated meters are permitted for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. M-Bus three-phase meter. Maximum current 3x80A, standby loss only 0.5 watts per path. Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rails. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With M-Bus interface. The directly measuring three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 external conductors with currents up to 80 A can be connected. The starting current is 40 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. Power consumption is indicated by a blinking LED that flashes 1000 times per kWh. It can also be used as a two-tariff meter as standard. 

5. Eltako Energy meter

Mobile three-phase energy meter with CEE plug 32A and CEE socket 32A. Suitable for indoor and outdoor use. Maximum current 32 A, standby loss only 0.5 watts per path. Housing dimensions 180 x 86 x 82 mm, connection cable 1.5 m (including plug and socket). Accuracy class B (1%). This mobile three-phase energy meter measures active energy based on the current between input and output. The internal power consumption of max. 0.5 watts active power per path is neither measured nor displayed. The inrush current is 40 mA. The display is only readable when the power supply is on. However, the consumption is stored non-volatile and immediately displayed after a power failure. The digital display is 7 digits. Up to 99999.99 kWh, two decimal places are shown. Above 100,000.0 kWh, only one decimal place is displayed. The power consumption is indicated by the LED blinking 100 times per kWh. 

6. Eltako MBusWandlerThree-phase meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. M-Bus converter three-phase meter with adjustable converter ratio and MID. Maximum current 3x5A, standby loss only 0.5 watts per path. Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rail. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With M-Bus interface. This three-phase meter measures active energy based on the currents flowing through the converters. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 converters can be connected with secondary currents up to 5A. The starting current is 10 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a LED that blinks 10 times per kWh. To the right of the display is... 

Eltako MBusWandlerThree-phase meter MID calibrated
Energy monitors
EUR209,74

Eltako MBusWandlerThree-phase meter MID calibrated

7. Eltako Air

The sensor is attached with its mounting magnet above the IR output of the meter and connected with its connection cable to the terminals Tx, Rx, GND, and +12V of the RS485 bus power meter data gateway FSDG14. 

8. Eltako Alternating current meter

Only calibrated meters are permitted for electricity billing according to § 25 of the German Calibration Act. Non-compliance is an administrative offense under § 19. Maximum current is 65 A, with a standby loss of only 0.4 watts. This is a modular device for mounting on a DIN-EN 60715 TH35 rail. 1 division unit = 18 mm wide, 58 mm deep. Accuracy class B (1%). Equipped with an S0 interface. This AC meter measures active energy based on the current flowing between the input and output. The self-consumption of only a maximum of 0.4 watts of active power is not measured or displayed. One external conductor can be connected with a current of up to 65 A. The starting current is 40 mA. If a load of more than 50% is expected, a ventilation distance of 1/2 division unit must be maintained from adjacent devices. If necessary, use the spacer DS12. Two N terminals for safe cross-wiring of multiple meters. The 7-segment LC display can also be shown twice within two weeks without power supply. 

9. Eltako ELTA three-phase meter

The ELTA three-phase meter from Eltako is a highly advanced measuring device designed for the precise recording of energy consumption and delivery in three-phase systems. With a maximum current of 3x80A and an accuracy class B (1%), this meter offers a reliable and efficient solution for energy monitoring. The meter is designed as a rail-mounted device for installation on a DIN-EN 60715 TH35 mounting rail and features a low standby loss of only 0.5 watts per path. The innovative S0 interface allows for easy integration into existing systems. The meter measures active energy by capturing the currents between the inputs and outputs and displays the results cumulatively. This means that both energy consumption and energy delivery are clearly and understandably shown on the digital display, facilitating easy reading and monitoring.

- Bidirectional three-phase meter for energy consumption and delivery
- Low standby loss of only 0.5 watts per path
- Cumulative energy measurement with clear display
- Energy consumption and delivery are stored non-volatilely
- 7-segment LC display allows reading without power supply.
 

10. Eltako Two-way three-phase current meter

The Eltako two-way three-phase meter is a highly advanced measuring device designed for the precise recording of energy consumption and delivery in electrical systems. With a maximum current of 3x80A, this Modbus two-directional three-phase meter offers a reliable solution for monitoring energy flow. The meter is designed as a rail-mounted device for installation on a DIN-EN 60715 TH35 mounting rail and is ideal for installation cabinets with an IP51 protection rating. The digital display allows for clear reading of measurement values, while the accuracy class B (1%) ensures high precision. The meter measures active energy by capturing the currents between the inputs and outputs and provides non-volatile data storage. The ability to connect 1, 2, or 3 external conductors makes it versatile.

- Modbus / RTU (RS485) interface for easy data transmission
- Low standby loss of only 0.8 watts at L1 and 0.5 watts at L2 and L3
- Balance measurement of energy consumption and energy delivery with clear display
- Suitable for connecting up to 3 external conductors with currents up to 80 A
- Energy consumption and delivery are stored non-volatilely.
 

Product order