1. Hager Helicopter 3 + N AC Switch B 10A 0.03A Type A 6kA Type RCBO (ADZ310D)

Residual current circuit breaker 3X 1PN 6kA B-10A 30mA Type QuickConnect. Residual current circuit breaker according to DIN EN61009-1 VDE 0664-20 with a single-pole circuit breaker for 230V AC circuits and a residual current protection circuit in a compact housing. QuickConnect terminal according to DIN EN 60898-1 VDE 0641-11, with a load capacity of up to 16 A at the output and up to 63 A at the input, blue test button, and residual current indicator. Easy individual removal from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device. ADZ310D. 

2. Hager CDA440D

Hager RCD CDA440D

Manufacturer: Hager
Designation: 4-pole RCD 40A/30mA, 6kA
Type: CDA440D
Number of poles: 4
Rated voltage: 400 V
Rated current: 40 A

Rated residual current: 0.03 A
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Power loss: 6.5 W
Mounting type: DIN rail
Residual current type: A
Selective type: no
Time-delayed type: no
Short-circuit strength (Icw): 6 kA
Surge current strength: 0.25 kA
Voltage type: AC
With locking device: yes
Frequency: 50 Hz
Additional devices possible: yes
Protection class (IP): IP20
Width in division units: 4
Installation depth: 70 mm
Ambient temperature during operation: -25..40 °C
Degree of pollution: 2
Connectable conductor cross-section multi-stranded: 1..16 mm²
Connectable conductor cross-section single-stranded: 1..25 mm²
RAL number (similar): 7005
Explosion-proof: no

Hager RCD CDA440D: additional details
4-pole residual current circuit breaker 6kA 40A 30mA Type A. Residual current circuit breaker (RCD) according to DIN EN 61008-1 (VDE 0664-10), DIN EN 61008-2-1 (VDE 0664-11) with Bi-Connect terminals at the bottom, external blue test button, and residual current indicator. Suitable for retrofitting additional devices. Connection terminals with wire insertion protection, labeling option directly on the device.
 

3. Hager CEC425J

The Hager CEC425J is a residual current protection block designed to protect electrical systems from hazardous fault currents. This protective switch is an essential component in electrical installations, as it helps minimize the risk of electric shocks and fires. With a high rated insulation voltage of 400 volts and a rated current of 25 amperes, the CEC425J offers a reliable solution for various applications. The residual current protection block is designed for use in alternating current systems and features a pole count of 4, making it versatile. Its compact design allows for easy integration into existing switch cabinets and installations.

- Rated fault current of 0.1 A for enhanced safety
- Fault current of 100 mA to prevent overloads
- Suitable for use in alternating current systems.
 

4. Hager HAG ADX420D FI-LS 4P 10kA B-20A 30mA A

Residual current circuit breaker 4P 10kA B-20A 30mA Type A. Residual current circuit breaker according to DIN EN 61009-1 VDE 0664-20 with a 4-pole circuit breaker for 400 three-phase circuits and a residual current protection circuit in a compact housing, blue test button, and residual current indicator. Easy single removal from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device. ADX420D. 

5. Hager ADZ316D

Residual current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole miniature circuit breakers for 230 V AC circuits and a residual current circuit breaker in a compact housing. QuickConnect connection according to DIN EN 60898-1, VDE 0641-11, for supply lines up to 16 A and for supply lines up to 63 A, touch protection according to IP2x DIN VDE 0106 Part 100, blue test button and residual current indicator. Easy individual removal from the phase busbar system. With VDE symbol. Suitable for retrofitting additional devices. Labeling option directly on the device. 

6. Hager Ground fault circuit interrupter

Hager RCD CPA463D

Manufacturer: Hager
Designation: RCD 4p. 63A/300mA Sel, 6kA
Type: CPA463D
Number of Poles: 4
Rated Voltage: 400 V
Rated Current: 63
A
Rated Residual Current: 0.3 A
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Withstand Uimp: 4 kV
Power Loss: 18.5 W
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: Yes
Time Delay Type: Yes
Short-Circuit Strength (Icw): 6 kA
Surge Current Strength: 5 kA
Voltage Type: AC
With Locking Device: Yes
Frequency: 50 Hz
Additional Devices Possible: Yes
Protection Class (IP): IP20
Width in Division Units: 4
Installation Depth: 70 mm
Ambient Temperature During Operation: -25..40 °C
Pollution Degree: 2
Connectable Conductor Cross-Section Multi-Wire: 1..16 mm²
Connectable Conductor Cross-Section Single-Wire: 1..25 mm²
RAL Number (similar): 7005
Explosion-Proof: No

Hager RCD CPA463D: Additional Details
4-pole residual current circuit breaker 6kA 63A 300mA Type S selective. Residual current circuit breaker (RCD) according to DIN EN 61008-1 (VDE 0664-10), DIN EN 61008-2-1 (VDE 0664-11) with Bi-Connect terminals at the bottom, external blue test button, and residual current indication. Suitable for retrofitting additional devices. Connection terminals with wire insertion protection, labeling option directly on the device.
 

7. Hager CDB663E RCD 4p 10kA 63A 30mA TypeB

Residual current circuit breaker, 10 kA, 63 A, 30 mA Type B. All-current sensitive residual current device (RCD), RCCB according to DIN EN 61008-1 VDE 0664-10, DIN EN 61008-2-1 VDE 0664-11, DIN EN 61543 VDE 0664-30, and DIN EN 62423 VDE 0664-40. Short-time delayed RCD for protection against smooth DC fault currents and AC fault currents in the frequency range up to kHz. Complies with the requirements of the installation standards DIN VDE 0100-410 and DIN VDE 0100-530. Suitable for retrofitting additional devices. Connection terminals with Bi-Connect terminals at the bottom, external blue test button, Type B. Operating indicator, top and bottom DIN rail slider for easy installation. Labeling option directly on the device. CDB663E. 

8. Hager CDB663D RCD circuit breaker 4p 10kA 63A 30mA TypeB+

Residual current circuit breaker, 10 kA, 63 A, 30 mA Type B. All-current sensitive residual current device (RCD), RCCB according to DIN EN 61008-1 VDE 0664-10, DIN EN 61008-2-1 VDE 0664-11, DIN EN 61543 VDE 0664-30, and DIN EN 62423 VDE 0664-40. Short-time delayed RCD for protection against smooth direct current and alternating current fault currents in the frequency range up to 100 kHz. The tripping within this frequency range up to 20 kHz occurs below 420 mA. Complies with the requirements of the installation standards DIN VDE 0100-410 and DIN VDE 0100-530. Suitable for retrofitting additional devices, tool-free installation. Connection terminals with Bi-Connect terminals at the bottom, blue test button, fault current indicator, Type B plus. Operational indicator, top and bottom DIN rail slider for easy installation. Labeling option directly on the device. CDB663D. 

9. Hager MCN363. Rated current: 63 A. Type: C-type, Module quantity (max): 3 module(s). Width: 52.5 mm

Hager Circuit Breaker MCN363

Manufacturer: Hager
Designation: 3-pole circuit breaker C-63A, 6kA
Type: MCN363
Installation depth: 70 mm
Tripping characteristic:
C
Number of poles (total): 3
Number of protected poles: 3
Rated current: 63 A
Rated voltage: 400 V
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Type of voltage: AC
Rated switching capacity Icn according to EN 60898 at 400 V: 6 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 10 kA
Frequency: 50..60 Hz
Power loss: 18.3 W
Energy limitation class: 3
Flush-mounted: yes
Switched neutral conductor: no
Overvoltage category: 3
Degree of pollution: 2
Additional devices possible: yes
Width in division units: 3
Protection class (IP): IP20
Ambient temperature during operation: -25..70 °C
Connectable conductor cross-section multi-stranded: 1..25 mm²
Connectable conductor cross-section single-stranded: 1..35 mm²
Explosion-proof: no

Hager Circuit Breaker MCN363: further details
3-pole circuit breaker 6kA C-characteristic 63A 3 modules. Circuit breaker according to DIN EN 60898-1 (VDE 0641-11) with delayed thermal trip for overload protection and electromagnetic trip for short-circuit protection. Suitable for retrofitting additional devices. Labeling option directly on the device and individual removal from the phase rail connection by releasing the DIN rail quick fastening.
 

Hager MCN363. Rated current: 63 A. Type: C-type, Module quantity (max): 3 module(s). Width: 52.5 mm
Residual-current device
EUR153,93

Hager MCN363. Rated current: 63 A. Type: C-type, Module quantity (max): 3 module(s). Width: 52.5 mm

10. Hager Fault arc protection

Arc fault detection device AFDD with RCD circuit breaker 1PN 6kA B-16A 30mA Type 3M. AFDD according to DIN EN 62606 VDE 0665-10, combined with RCD circuit breaker 1PN according to DIN EN 61009-1 VDE 0664-20, DIN EN 61009-2-1 VDE 0664-21, with differential current monitoring Type 30 mA, with QuickConnect terminal according to DIN EN 60898-1 VDE 0641-11, blue test buttons for the AFD unit with arc fault indication and residual current indication. Easy single removal from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device. ARF916D.