ABB High-performance circuit breaker
Product details
The high-performance circuit breakers of the S800N series protect cables and wires from overload and short circuits. They have a rated short-circuit breaking capacity of 36 kA at 240/415 V AC. Additionally, they can be used for voltages up to 400/690 V AC and for direct currents. With its thermal trip mechanism, it provides effective protection against overload, while its electromechanical trip mechanism offers protection against short circuits. The S800N complies with the IEC/EN 60947-2 standard, making it suitable for industrial applications. Numerous approvals make it ready for global use, and the extensive range of accessories enhances usability. Thanks to its very fast arc extinction, your installation is well protected with the S800N.
Circuit breaker type | Circuit breaker |
Length | 82.50 mm |
Width | 27 mm |
number of poles | 1 |
Mounting type | Top-hat rail |
Item number | 34663214 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 2CCS891001R0104 |
Release date | 17.5.2023 |
Colour | Grey |
Exact colour description | Grey |
Circuit breaker type | Circuit breaker |
Mounting type | Top-hat rail |
number of poles | 1 |
Tripping characteristic | C |
Rated current | 10 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 690 V |
Residual current (rated differential current) | 36000 A |
Protection type (IP code) | IP20 |
Country of origin | Switzerland |
Manufacturer commitment | SBTi |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 82.50 mm |
Width | 27 mm |
Height | 95 mm |
Weight | 245 g |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
- 5.Hager0,2 %
- 7.Steffen0,7 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Brennenstuhl1,6 %
- 3.Schneider Electric1,7 %
- 4.ABB1,9 %
- 5.Eaton3,3 %
- 6.Siemens3,6 %