Eaton MOE FRCMM-40/4/003-A RCD switch, 40A, 4p, 30mA, type A
rated current2
Residual current (rated differential current)2
Product details
Design of a voltage-independent residual current circuit breaker for industrial and commercial applications with high rated current. Double comfort terminal (lift/spade), with red-green contact position indication on both sides. The function of the switch is independent of its position. Application notes: The residual current circuit breaker and its tripping are independent of the mains voltage, allowing use in all access areas. The residual current circuit breaker is suitable for providing fault protection, additional protection, and/or fire protection. The requirements of the relevant installation regulations (e.g., IEC/EN 60364) apply.
Test button: The test button "T" should be pressed every 6 months. The operator of the system must be informed of this requirement and its responsibility in a verifiable manner. Under special conditions (e.g., damp and/or dusty environments, environments with contaminating and/or corrosive conditions, environments with high temperature fluctuations, installations with risks of overvoltage due to switching devices and/or atmospheric discharges, mobile power supply units), it is recommended to test monthly. The provisions of the installation regulations regarding special applications and environments apply. If the device simultaneously shows a red and yellow LED, the test button must be pressed, and the steps in the installation instructions must be followed. Pressing the test button "T" only tests the function of the residual current (RCD) circuit breaker. This test does not replace the measurement of earth resistance or the proper testing of the protective conductor, which must be carried out separately.
Circuit breaker type | Fault current circuit breaker |
Length | 70.50 mm |
Width | 4 mm |
number of poles | 4 |
Mounting type | Top-hat rail |
Item number | 32103440 |
Manufacturer | Eaton |
Category | Residual-current device |
Manufacturer no. | 170333 |
Release date | 16.11.2022 |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 40 A |
Rated current | 0.03 A |
Rated voltage | 415 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 440 V |
Residual current (rated differential current) | 0 A |
Protection type (IP code) | IP20 |
Country of origin | Serbia |
Manufacturer commitment | SBTi |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 70.50 mm |
Width | 4 mm |
Length | 9 cm |
Width | 7 cm |
Height | 7 cm |
Weight | 970 g |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
- 5.Hager0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- EatonNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 3.Brennenstuhl1,7 %
- 4.ABB1,9 %
- 5.Eaton3,3 %
- 6.Siemens3,6 %
- 7.Hager4,9 %