Schneider Electric A9Z24 FiCircuit breaker iID
More than 10 pieces in stock at supplier
Rated current2
Residual current (rated differential current)2
Product details
Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 100A, earth fault sensitivity 30mA, earth fault protection class type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Provides additional protection against direct contact (≤ 30mA). Fault protection against indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site distribution boards (500mA). Switching and isolating circuits. Jump switching for low-wear contact operation. Equipped with a mechanical front-side fault indication (VisiTrip) to show tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the residual current circuit breaker, with a green indication ensuring voltage-free safety on the outgoing side. Test button for regular functional testing. Double connection terminals for dual-sided connection of cables or busbars. Easy removal of the individual device when a busbar is installed, thanks to the front-accessible fastening element. Additional snap-on auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), working current release (iMX), auxiliary switch for status indication (iOF), fault indication switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards - IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified.
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Length | 44 mm |
Width | 72 mm |
Item number | 12900663 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | A9Z21491 |
Release date | 12.3.2020 |
Colour | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Rated current | 100 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | France, Spain |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 18,08 kg |
Climate contribution | EUR 0,44 |
Items per sales unit | 1 pcs. |
Length | 44 mm |
Width | 72 mm |
Height | 91 mm |
Weight | 370 g |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 4.ABB0,1 %
- 4.Schneider Electric0,1 %
- 6.Hager0,2 %
- 7.Steffen0,5 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,3 %
- 5.ABB2,2 %
- 6.Siemens3,4 %