Your data. Your choice.

We use cookies and similar technologies to provide you with the best shopping experience as well as for marketing purposes. Please accept, decline or manage the use of your information.

Best selling Surge protection

Here's a ranking of the best products in this category. To give you a quick overview, we've also added some key information about the products.

1. Ubiquiti ETH-SP-G2: Surge Protect Gen.2

The Ubiquiti Ethernet Surge Protector Gen 2 redirects harmful electrostatic discharges and surges safely into the ground, ensuring that outdoor devices connected to the Ethernet port remain protected at all times. The Ethernet Surge Protector Gen 2 is designed to protect both PoE and non-PoE network devices at speeds of up to 1000 MBit/s. 

Ubiquiti ETH-SP-G2: Surge Protect Gen.2
Surge protection
Quantity discount
EUR13,20 per piece for 2 units

Ubiquiti ETH-SP-G2: Surge Protect Gen.2

2. Eaton SPZT123-300/3+NPE-S EP-501043 Lightning current surge arrester EP-

For the protection of consumer installations in the network connection area of the meter cabinet on a 40 mm busbar against transient overvoltages caused by direct and indirect lightning strikes as well as switching actions. Meets all requirements for the installation of surge protection according to DIN VDE 0100-534, test classes I, II, III according to IEC 61643-1, SPD type T123, complies with IEC 61643-11: 2011, EN 61643-11:2012 A11:2018, lightning protection classes III and IV according to IEC 62305, free of leakage current, with integrated fuse for the protection of the Smart Meter Gateway and the APZ SPZT123-3003NPE-S. 

Eaton SPZT123-300/3+NPE-S EP-501043 Lightning current surge arrester EP-
Surge protection
EUR197,–

Eaton SPZT123-300/3+NPE-S EP-501043 Lightning current surge arrester EP-

3. Dehn DG M TNS 275

Multipole surge arrester DEHNguard M, type 2 according to EN 61643-11, consisting of a base part and plug-in protection modules. High device safety due to arrester monitoring with thermo-dynamic control. Designed for the protection of low-voltage consumer equipment against overvoltages. Suitable for use in the lightning protection zone concept at interfaces 0B-1 and higher. 

4. Hager SPV340

The Hager SPV340 is a Type 2 surge protector specifically designed to protect electrical systems from transient overvoltages. With its three-part design, this device is ideal for mounting on a DIN rail and provides a reliable solution for the protection of PV systems. The SPV340 ensures a high nominal voltage of 1000 volts and a nominal discharge current of 15 kiloamperes, making it a robust choice for various applications. The IP20 protection rating ensures that the device can be used in dry indoor environments, while the protection level of 3.7 volts offers effective safeguarding against overvoltages. Manufactured in Germany, the Hager SPV340 combines quality and reliability in a compact design.

- Type 2 surge protection for reliable safeguarding
- Three-part design for easy DIN rail mounting
- Nominal discharge current of 15 kA for high durability
- Protection level of 3.7 V for effective surge protection
- Made in Germany for high quality standards.
 

Hager SPV340
Surge protection
−27%
only 1 piece on sale
EUR71,– was EUR97,26

Hager SPV340

5. Dehn shield ZP

Combined lightning current and surge arrester for TT and TN-S systems for use in the main power supply system (3+1 circuit) in residential buildings without external lightning protection, including overhead line feed, with overcurrent protected 230 V power supply for RfZ / APZ according to VDE-AR-N 4100. 

6. Hager Surge arrester

Hager surge arrester SPB413

Manufacturer: Hager
Designation: Surge arrester
Type: SPB413
DC network form: No
IT network form: No
TN network form: No

TN-C network form: No
TN-C-S network form: No
TN-S network form: Yes
TT network form: Yes
Number of conductors (excluding Earth): 4
Nominal surge current (8/20): 20 kA
Maximum surge current (8/20): 40 kA
Nominal voltage AC: 400 V
Highest continuous voltage AC: 275 V
Max. PV voltage: 0 V
Protection level: 1.35 kV
Protection level L-N: 1.35 kV
Protection level N-PE: 1.6 kV
Max. overcurrent protection device for wiring (fuse): 125 A
Max. overcurrent protection device for V-wiring (fuse): 80 A
Short-circuit strength (Isccr): 25 kA
Integrated short-circuit protection: No
Integrated selective short-circuit protection for gG fuse: 125 A
Integrated pre-fuse: No
Leakage current free: No
Mounting type: TH35 rail
Size: 4 TE
Max. conductor cross-section rigid (single/multi-stranded): 35 mm²
Max. conductor cross-section flexible (fine-stranded): 25 mm²
With remote monitoring contact: No
Device signaling: Optical
Test class type 2: Yes
Protection class (IP): IP20

Hager surge arrester SPB413: Additional details
Surge arrester T2 4P 40kA TT/TN-S fault indication. Type 2 surge arrester in a 3+1 configuration, designed to protect three-phase TT and TN-S systems. Comprising a fourfold base element, three protective plugs with temperature-monitored high-performance varistors, and one plug as a total current spark gap with a dynamic disconnection device. Optical fault indication on the plugs in case of overload. Connections for the active conductors from below and for Earth/PE from above. Biconnect terminals for connecting round conductors and wiring bridges. Labeling option on the base element.
 

7. Dehn DEHNshield ZP DSH ZP B TT 255

The combined surge arrester for the 40 mm busbar system is specifically designed for residential buildings without external lightning protection. The proven spark gap technology allows for use in the pre-meter area and fully complies with the VDN guidelines. With a high nominal discharge current, the DEHNshield ZP Basic meets all requirements of the new DIN VDE 0100-534. Additionally, the corresponding lightning current discharge capacity fulfills the normative requirement for the installation of a Type 1 arrester for overhead line connections. The arrester, with coordinated protective effects according to Type 1, Type 2, and Type 3, also provides equipment protection. 

8. Dehn SOEHNE UESAbleiter guard

Multipole surge arrester DEHNguard M, type 2 according to EN 61643-11, consisting of a base part and plug-in protection modules. High device safety due to arrester monitoring with thermo-dynamic control. Designed for the protection of low-voltage consumer equipment against overvoltages. Suitable for use in the lightning protection zone concept at interfaces 0B-1 and higher. 

9. Dehn Built-in overvoltage protection Übe

Surge arrester for all installation systems at the terminal level. Compact design for use in cable duct systems and flush-mounted boxes.

10. Eltako 28380001 MUA-50 Überspannungsschutz-Ableiter 1 St.

Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rails. TÜV certified according to IEC 61643-11, certificate number: AN 50567910 0001. 4 division units = 72 mm wide. The modular combined surge protector reliably protects electrical systems from transient overvoltages. It offers high protection against direct lightning strikes in TT, TN-C, and TN-S systems. 12.5 kA surge current resistance per pole. Easy rail mounting and modular design enable quick installation and maintenance. Combines protection classes Type 1+2+3 in one device, providing comprehensive surge protection from the building entry to the end device. The use of a MUA-50 combined surge protector is mandatory according to DIN VDE 0100-443/534 for new buildings and expansions with high-power consumers (e.g., wall box, heat pump, PV system). If external lightning protection is present, a protection level is required: Type 1 in the main distribution (e.g., MUA-100, MUA-50) and Type 2 in the sub-distribution (e.g., MUA-30, MUA-20). A Type 2 surge protector in the sub-distribution is only required if the line length to the main distribution with installed Type 1+2+3 exceeds 10 meters. 

Eltako 28380001 MUA-50 Überspannungsschutz-Ableiter 1 St.
Surge protection
EUR145,71

Eltako 28380001 MUA-50 Überspannungsschutz-Ableiter 1 St.

Product order
See all products